Spectral Dynamics becomes Aspedyn.

Calibration of measurement systems

The accuracy of measurement systems can drift over time. Regular calibration of your controllers, sensors, and PIND systems is therefore necessary to maintain the reliability and accuracy of your measurements. Standards applicable to environmental testing specify the need for regular verification of measuring equipment. The frequency of these checks should be defined by your Quality Management System. The most commonly applied interval is 12 months.


Spectral Dynamics controller calibration

Aspedyn offers a comprehensive support and calibration service for Spectral Dynamics controllers. These services are performed by our technicians, either at the customer's site or in our offices in France.

If you require a Cofrac certificate (or equivalent), Aspedyn also offers a calibration service according to the ISO 17025 standard for Lynx™, Puma™, Panther™ and Jaguar™ controllers.

Calibration of PIND systems

Aspedyn offers a calibration service for all PIND systems, from the PIND 4501 model to the PIND Felix™. A PIND calibration includes the following operations:

  • inspection of the different components of the PIND system: controller, shaker and sensors; ;
  • monitoring of the overall operation of the system; ;
  • verification of vibration levels, shocks and acoustic detection thresholds; ;
  • calibration and/or verification of the following components:
    • the acoustic detection crystal; ;
    • the sensor's accelerometer; ;
    • the acoustic emitter of the STU; ;
    • the STU signal generation unit; ;
    • the PIND controller, with adjustment of offsets and values to obtain the required levels of acoustic, vibration and shock detection; ;
    • the display system used to visualize particle noise; ;
  • final verification of the operation of the entire system; ;
  • writing the report, applying the calibration label and saving all measurements taken.
Calibration

Calibration of accelerometers and sensors

Aspedyn offers an accelerometer calibration service. Our main test bench is equipped with a dedicated TIRA TV51140C shaker and a Spectral Dynamics Lynx™ controller, ensuring accurate measurement.

This system exhibits very low transverse stress and allows for high frequencies. The standard calibration of accelerometers extends from 5 Hz to 5 kHz for IEPE or load cells. Upon request and depending on the accelerometer type, the frequency range can extend from 1 Hz to 10 kHz.

Each sensor is returned with a full certificate and calibration label.

As part of a personalized maintenance contract, Aspedyn takes care of all the services necessary for the monitoring, maintenance and proper functioning of your equipment.

As part of a personalized maintenance contract, Aspedyn takes care of all the services necessary for the monitoring, maintenance and proper functioning of your equipment.

Contact us